Model No.︰KULUN-060
Brand Name︰KULUN
Country of Origin︰China
Unit Price︰CNY ¥ 5000000 / pc
Minimum Order︰1 pc
TECHNICAL PARAMETERS
1. Gas treatment capacity: m3/h, can be designed according to actual requirements from customers.
2. Normal flue gas temperature: 120-180ºC
3. Allowed max gas temperature: 250ºC
4. Allowed dust rate resistance: 104 -1011Ω/cm
5. Flue gas dew point: 60~65ºC
6. Dust concentration at flue gas inlet : <20(g/m3)
7. Dust concentration at flue gas outlet: <50 (mg/m3) , or to be designed according to requirements.
8. Controls: automatic control
STANDARD SPECIFICATIONS (EXAMPLE)
No. |
Items |
Value |
1 |
effective cross sectional area(m2) |
28 |
2 |
Flue gas capacity(m3/h) |
36000 |
3 |
Gas velocity through ESP(m/s) |
0.36 |
4 |
Spacing between collecting plate(mm) |
400 |
5 |
Length of electric field(m) |
2*3 |
6 |
Number of passages |
10 |
7 |
Type of corona wire |
BS wire |
8 |
Rows of corona wire |
10 |
9 |
Rapping method of corona wires |
Flexible arm |
10 |
Rapping method of corona wires |
Flexible arm |
11 |
Rapping method of collecting plate |
Flexible arm |
12 |
Type of collecting plate |
C480 |
13 |
Rows of collecting plate |
11 |
14 |
Total area of collecting plate(m2) |
840 |
15 |
Effective height of collecting plate(m) |
7 |
16 |
Treatment time(s) |
16.7 |
17 |
Allowed pressure (Pa) |
+200~-5000 |
18 |
Pressure drop(Pa) |
<300 |
19 |
Allowed max flue gas temperature (ºC) |
250 |
20 |
Dust concentration at flue gas inlet (g/m3) |
<20 |
21 |
Dust concentration at flue gas outlet (mg/m3) |
<50 |
22 |
Designed dust collecting efficiency |
99.5% |
23 |
High-voltage constant current power supply |
0.2A/100KV×2 sets |
Payment Terms︰ T/T